Datexel

Modbus Acquisition Modules Master's, Slaves, Controllers, Data Loggers.

Modbus Acquisition Modules Master's, Slaves, Controllers, Data Loggers.

Datexel has a range of Modbus RTU Masters, Slaves, Controllers, Data Loggers and RS485 Isolators, Repeaters and Converters. The DAT9000 is a Modbus RTU Master with RS485, RS232 and Ethernet Interfaces. The DAT9000IO is similar to The DAT9000 but it has digital input and outputs. The DAT9000DL has an additional datalogging facility and the DAT9000DLIO has both datalogging and digital IO. The DAT9011 is a Modbus Master with 2 analog inputs which can chose from Thermocouple's, RTD's, Potentiometers, mA and mv's. It also has 2 outputs which can be mA or voltage. The DAT9011 can also accept digital inputs and provide 2 SPDT relay outputs. The DAT9011DL also has a datalogging facility which can store up to 8 gb of readings on a thumb drive. The unit can log internal and external registers on the Modbus network. Both the DAT9000 and the DAT9011 can be programmed by the Ethernet port and DAT9000 software development package provided by DATEXEL free of charge from the Datexel download web page. The DAT3500 series is a range of converters, isolators and repeaters. The inputs and outputs can be RS485, RS422, RS232, or Ethernet TCP-IP. Whilst converting this signal the devices also isolate the input from the output and the power supply. They can also be used if the range (distance) needs to be extended.

 

Modbus RTU Intelligent Units

Modbus RTU Master and Slave

Modbus RTU Master

Input None

Output RS232, RS485, Modbus TCP

Modbus RTU Master & Slave with Digital IO

RS485 Modbus RTU Master DAT9000IO with Digital inputs and relay outputs

Input 4 Digital inputs

Output 2 Relays, RS232, RS485, Modbus TCP

Modbus RTU Master & Slave with Datalogging

Modbus Data Logger DAT9000DL

Input None

Output RS232, RS485, Modbus TCP, Logging.

Modbus RTU Master & Slave with IO & Logging

DATA Logging RS485 Modbus with Digital IO

Input 4 Digital inputs

Output 2 Relays, RS232, RS485, Modbus TCP and Logging.

Modbus Master & Slave Analog and Digital IO.

Modbus Analog and Digital IO

Input V, I, RTD, T/C's, 2 Digital.

Output 2 x 4-20mA

Modbus Master & Slave Analog, IO, USB Logging.

Modbus Data Logger

Input V, I, RTD, T/C's, 2 Digital.

Output 2 x 4-20mA

 

Modbus Remote Display and RTU Isolated Converters

Modbus Remote Display Indicator

Modbus Remote Display

Input Modbus RS485, RS232,

Output 132 X 32 Pixels with back light.

RS232 to RS485 Isolated Converter

RS232 to RS485 Isolated Converter

Input RS232

Output RS485

RS232 to RS422 Isolated Converter

RS232 to RS422 Isolated Converter

Input RS232

Output RS422

USB to RS485 Isolated Converter

USB to RS485 Isolated Converter

Input USB

Output RS485

USB to RS422 Isolated Converter

USB to RS422 Isolated Converter

Input USB

Output RS422

Modbus to Ethernet Isolated Converter

Modbus to Ethernet Converter and gateway for Modbus RTU

Input RS485

Output Ethernet

Modbus Isolated Repeaters